Disadvantage of Low Power Factor | Causes 10 Points |

Disadvantage of Low Power 

Disadvantage of Low Power and Causes of low power factor , In this post you will know about what is causes and disadvantages of low power factor in electrical engineering .

Power Factor 

The power factor of a circuit can be defined as one of the following way

Disadvantage of Low Power Factor
Disadvantage of Low Power Factor


1. The cosine of angle between Voltage (V)and current (I) is known as power factor
2. it is the ratio of Resistance and Impedance
              Power factor=R/Z= Resistance\Impedance
3.It is the ratio of true power and Apparent power
             Power Factor = True Power/Apparent Power 
For example , in a resistor , the current and voltage are in phase . Therefore, power factor of a pure resistive circuit is cos 0=1. Similarly , phase difference between voltage and current in a pure inductive or capacitive circuit is 90 degree.Hence power factor of pure L or c circuit is zero. This is the reason that power consumed by pure L or c is zero. 

Cause of low power factor

The following are the main causes of low power factor
  1. Transformers , generator and chocks are inductive loads which causes the current to lag behind the voltage. i.e., they operate at a lagging power factor . However , at normal loads , the magnetising current does not effect and lowers the power factor.
  2. The motors which are used in industries are mostly induction motors having inductive loads, which have low power factor . Normally the power factor of induction motors varies from 0.8 to 0.85
  3. Arc laps , heating furnaces ( Induction and are furnaces also operate at low power factor (lagging)

What are the disadvantage of low power Factor 

The higher current result in the following disadvantages 

  1. Large conductor size : To transmit or distribute a fix amount of power at a fixed voltage at low power factor , the conductor will have to carry larger current which will necessitate a large conductor size.
  2. Large Copper Losses : Due  to more current carried by the conductor , large copper losses 
  3. Poor Voltage Regulation : Due to power factor and increased currents, the voltage drop in transformers , alternators and transmission/ distribution lines is higher which results in poor voltage regulation
  4. Large KVA rating of the equipment :  the output power of electrical machines e.g. alternators and transformers is always rated in apparent power 
  5. Poor Efficiency : Due to the low power factor efficiency of all our system is decreased . 
I think this information about disadvantage of low power and causes of low power factor will helpful for you . if you have more question then Comment us your question below 

Comments

Popular posts from this blog

Top 10 Government Polytechnic Colleges in Haryana

Top government  polytechnic college in Haryana . Haryana is a state of India. The capital of this state is Chandigarh. And this state is highly recommended for the technical education. So according to current updates (2/10/2016).  We are shearing with you about for top 10 government polytechnic colleges of Haryana. here is the list of top government polytechnic college in haryana & also total no of government  polytechnic college in Haryana. top 10 governent polytechnic colleges in haryana This information is provided by the By the HSBTE Directorate of Technical Education Haryana, Panchkula Haryana is a State Authority under the control of State Government. Principal of Directorate of Technical Education Haryana, Panchkula Haryana is Shri Dhanpat Singh. Directorate of Technical Education Haryana, Panchkula, Haryana Address:Govt of Haryana Baya No. 7-12, Sector 4 Panchkula (District Panchkula) Haryana, India Pin Code : 134112 Website 

Ramakrishna Mission Deoghar Admission Form |Fee Structure & Syllabus | 2018

Ramakrishna Mission Vidyapith Deoghar Admission 2018  If you are looking to take admission in  Ramakrishna Mission Deoghar , Jharkhand , Then this is very good idea.Here we are sharing with you about ,Admission process to take admission in RK Mission Deoghar. Before going towards Admission process information you should have must know about RK Mission Deoghar About RK Mission Deoghar Ramakrishna Mission Vidyapith, Deoghar  is a senior secondary school in  Deoghar ,  Jharkhand ,  India , This is established in 1922. This school is  affiliated to the  Central Board of Secondary Education (CBSE). Admission to its Secondary section is restricted to standard VI only.This  school offers education in science stream only in for  Senior Secondary Section. Ramakrishna Mission Vidyapith, Deoghar was ranked 4 out of all CBSE schools in India in 2015. Ramakrishna Mission Deoghar  Address : Ramakrishna Nagar, PO : Vidyapith, Deoghar-814112, Jharkhand  Phone (06432) 222413,

Advantages of A.C over D.C. | Alternating Current & Direct Current |

Advantages of A.C over D.C. list of few advantages of A.C. supply over D.C. Supply are :These are the some following major advantages of Alternating current over direct current Advantages of A.C over D.C 1. A  supply voltage can be raised or lowered by using transformer in A.C. as per requirement. It is not easy to do in the case of D.C. Supply. 2. For a given size of machine , the power generated in three phase alternator is three times the power generated in d.c. generator .Smaller size of machine make it cheaper  3. Generation of power at high voltage is easier in the case of a.c. than the case of d.c. generation.It is because of commutation problem in d.c. generation 4. For transmission of a given amount of power over a given distance at a given voltage , the conductor material required in the case of three phase a.c. system is less than conductor material  required in two wire d.c. system 5.In case of 3 phase , 4 wire system two different voltages 230